Install Guide

SENSIT SYSTEM | MANUAL
Mounting The SENSIT IR
51/118
11 MOUNTING THE SENSIT IR
SAFETY PRECAUTIONS
The following safety precautions should be observed during normal use, service and
repair:
The SENSIT IR may only be installed and serviced by qualified service
personnel.
To be sure of safety, do not modify or add anything to the SENSIT IR other
than mentioned in this manual or indicated by NEDAP N.V.
IC AND FCC ID
FCC ID: CGDSENSIT and IC: 1444A-SENSIT
DIMENSIONS
The SENSIT IR is designed for mounting into the floor of a parking space. See Figure
34 for the dimensions of the unit in mm.
Figure 34: Dimensions SENSIT IR (mm).
INSTALLATION CONDITIONS
The installation recommendation is based on the following environmental
conditions;
Ambient temperature between 5 to 40 °C (41 to 104 °F0
Dry weather conditions
Surface based on concrete, asphalt or pavement
REQUIRED INSTALLATION MATERIALS
The following would be required for mounting of the SENSIT IR.
Equipment: Automatic core drill
Drill size: Dimensions Ø 85 mm (3.35 in)
Drill depth: 55 mm (2.16 in)
Filler material: Liquid rapid mortar
Required amount per sensor: Approx 100 ml
We have good results with the rapid mortar TM 5R. See appendix B for
specifications. Ensure to follow the guidelines and instructions as outlined on the
filler material.