mounting The SENSIT (IR) Flush Mount
58/118
Sensor
Diameter (A)
Diameter (B)
Fill up to (C)
Maximum
93 mm
3 11/16 inch
75 mm
2 61/64
47 mm
1 7/8 inch
Recomme
nded
90 mm
3 9/16 inch
75 mm
2 61/64
50 mm
2 inch
Minimum
87 mm
3 7/16 inch
75 mm
2 61/64
54 mm
2 1/8 inch
Figure 36: Drilling dimensions and glue fill-up height.
REPLACEMENT
When the battery life of the SENSIT Flush Mount fails after specified life time, we
advise to replace the unit completely. The SENSIT Flush Mount is fully sealed,
therefore batteries cannot be replaced. Drill out the old SENSIT Flush Mount and
complete the mounting procedure as described in paragraph 11.6.
Ensure to note the node ID number of the SENSIT IR to the parking bay. Update the
parking bay configuration list in the SIS software to ensure the new sensor is linked
to the right parking bay.
MAINTENANCE AND CLEANING
In principle the SENSIT IR Flush Mount sensors are maintenance free and the surface
of the sensors is self-cleaning, dirt won’t attaches very easy to it. In some special
circumstances the self-cleaning doesn’t work very well. Basically when the sensor is
installed at location where it hardly rains, like in the middle east or at a covered
parking lot the cleaning mechanism might not work properly. In this case Nedap
recommends to clean the sensor lenses regularly based on our experience a 3
monthly cleaning interval is sufficient.