Installation Instructions
connector explanation
GND Power connector Ground Voltage ripple <125mV
+12V Power connector +12VDC
LED + Led output connector + The led will ash 3x at deactivation
LED - Led output connector - and once on detection.
Out C Output Common Solid state output (max 120mA)
Out NO Normal open
Inp A Input anode 0 - 12V
Inp K Input Kathode High signal, input >2V
+12V + It is possible, by using a special
RS485 A RS485 connector A RS485 converter and software, to
RS485 B RS485 connector B adjust some settings.
GND -
c
no
G3VM-351A
OC1
solid state output
kathode (-)
anode (+)
GND
Input