User's Manual

COMBI-BOOSTER
© Nedap IDEAS, P.O. Box 103, NL-7140 AC GROENLO Page 10 of 11
7.3 READING THE OPERATING MODE
Use NEDAP iTerminal and a XS110W to read/write the operating mode.
Send the following command to the XS110W to read the current operating mode:
01311980??
The combi-booster will respond with a data message to the reader. This data contains the combi-
booster's firmware name and version and also the current operating mode. The following replies are
possible (the characters 'cbvv' indicate the combi-booster's firmware name and version):
010120U0000000000cbvv098000
Mode A (default)
010120U0000000000cbvv098001
Mode B
010120U0000000000cbvv098002
Mode C
010120U0000000000cbvv098003
Mode D
010120U0000000000cbvv0980??
Operating mode was not programmed. Mode A is used.
7.4 WRITING THE OPERATING MODE
The operating mode is programmed in the same way the vehicle-id number is programmed.
Use NEDAP iTerminal and a XS110W to read/write the operating mode.
Send the following command to the XS110W to program operating mode A: 0131190000
Send the following command to the XS110W to program operating mode B: 0131190001
Send the following command to the XS110W to program operating mode C: 0131190002
Send the following command to the XS110W to program operating mode D: 0131190003
The reply message should echo the last 4 characters of the command message otherwise the
programming has failed.