User's Manual

© Nedap N.V. Nedap Readers Installation Guide
Page 13 of 21
R
GND
UL*/NA* / BEEP
4. Convexs/Invexs connections
The Convexs/Invexs is not hot-swappable, so when making or changing connections be sure power is Off.
General:
- Check corresponding documentation of used AEpacks, Convexs converters and third party systems.
- Use correct shielded cables, cable shield must be connected to Power GND of Convexs (A2) Invexs (2)
and GND of external device (or metal case)
- Beeper can also optional be controlled by configuration settings (see chapter 5).
- Check for Invexs 190 cabling colours
4.1. Convexs Connections
4.2. Invexs 170 Connections
4.3. Invexs 190 Connections
Remark:
UL*,NA*, MD* and BEEP are Open Collector to GND.
If Convexs adapters (AX1014 or AB350) are used, the original UL and NA signals
of the reader are converted to be used with UL* and NA* of the Convexs/Invexs.
Invexs 190 to AX1014 or AB350 needs additional connection between GND (for UL and NA) and
Antenna GND on the AX1014 / AB350 (Invexs 190 has no separate cable for this connection)
Convexs
Function
A1
Power /
XSMOD
Power in (10-30VDC) /
XS modulator (120kHz)
A2
POWER GND/shield
Power Ground
A3
A (-)
RS485
A4
B (+)
RS485
A5
D0
Wiegand Data 0
A6
D1
Wiegand Data 1
A7
BEEP
Beep input
A8
UL*
UL led input
A9
GND
Led/Beep Common Ground
A10
NA*
NA led input
Convexs Rear view
Invexs
Function
1
Power /
XSMOD
Power in (10-30VDC) /
XS modulator (120kHz)
2
POWER GND/Shield
Power Ground
3
A (-)
RS485
4
B (+)
RS485
5
D0
Wiegand Data 0
6
D1
Wiegand Data 1
7
BEEP
Beep input
8
UL*
UL led input
9
GND
Led/Beep Common Ground
10
NA*
NA led input
1
10
1
10
5
1
6
1
Invexs with display
Invexs without display
Wire
Colour
Function
w1
Red
Power in (10-30VDC) /
XS modulator (120kHz)
w2
Black
Power Ground / RF Ground
w3
Grey
RS485 A (-)
w4
Violet
RS485 B (+)
w5
Green
Wiegand Data 0 (D0)
w6
White
Wiegand Data 1 (D1)
w7
Yellow
Beep input (BEEP)
w8
Pink
UL led input (UL*)
w9
Blue
MD led input (MD*)
w10
Brown
NA led input (NA*)
w11
Shield / Metal
EM shield (connected to power ground)
E
Cable shield (wire 11) must be
connected to the metal case of
the external device