User's Manual

© Nedap N.V. Nedap Readers Installation Guide
Page 19 of 21
10. Available reader firmware
Pay attention that not for all output protocols suitable firmware is available at the applied readers.
The Nedap RF badge can always be used on Nedap readers. Wiegand formats can always be used on APx003
series with corresponding firmware.
For the Nedap RF data and RS485NR not for all readers the suitable firmware is available. Please check always
for the correct firmware version.
Nedap RF data
RS485NR
Remarks
AP1001
AP1001_548v210
X
AP1002
AP1002_548v211
X
AP1009
AP1009_548v211
X
AP4001
AP4001_543v204
X
AP4001X
AP4001_543v305
X
AP1003
X
AP1003rs485NR2_543v200
AP1003rs485NR_543v200
AP4003
X
AP4003rs485NR2_543v210
AP4003X
X
AP4003rs485NR2_543v210
AP4003rs485NR_543v31x
See remark AP4x03
below
AP6003
X
AP6003rs485NR2_2368v100
AP6003rs485NR_2368v100
Accessor III on AEOS
A3PNU_AEOS_v2.01
X
SimpleXS on AEOS
A0PNU_AEOS_v2.01
X
AC3/2TR on AEOS
H7A3U_AEOS_v2.02
X
Remarks:
X in above table means NOT possible.
Two RS485 protocols are available:
o rs485NR2 (up from 8-2009) able to show the Convexs/Invexs as an AEpack in AEmon,
offering full implementation for AP4x03 and AP4x03X (PIN, tamper switch) and additional
features such as Beeper control over RS485.
Can be used for all most corresponding AEpacks (including AP4x03).
Highly preferable to use always this protocol!
o rs485NR: Convexs/Invexs is not visible in AEmon, only AEpack to it is connected is shown.
First implementation of rs485NR protocol.
Not available for AP4x03. The AP4x03 (RS485NR) is only available for the X version up from
version v3.1x, and must have at least Kernel version 3.10.
Tamper switch and PIN not available at the AP4x03X, only at the AP1003 with RS485.
AP4003X (rs485NR) / AP4003 (rs485NR2) connected to
o AP8001X: needs AP8001X_543v302 or higher
o AP8001: needs AP8001_543v102 or higher (and kernel for AP8001 version 1.04 or higher)
o AP4801X, AP4803X, AP4807X: needs kernel 3.11 or higher
o AP4801, AP4803, AP4807: needs kernel 2.11 or higher
For XS readers connected to WinXS Nedap RF data is not possible (use always RF badge).
When using RS485 check if the applied AEpack is equipped with RS485 interface. Otherwise the
AX1012 (RS232 to RS485 converter) must be placed at the AEpack).
10.1. AEOS versions
The Convexs/Invexs can be connected to AEOS for (almost) all versions; in-depending of the communication
method between the AEpack and Convexs/Invexs (the AEpacks must have the correct firmware, see above).
If the Convexs/Invexs is not supported by an older AEOS version, the data from the card will still be read by
AEOS and normal handled, It is not possible to see these Convexs/Invexs in AEmon or to load (using AEmon) a
new configuration in the Convexs/Invexs (in case RS485 is used):
Up from 2.2.0 Convexs/Invexs supported
Up from 2.1.7 / 2.2.0: Primary and secondary identifier type at Access Points