Convexs 80
Nedap Mifare dual technology readers
GENERAL
The Convexs reader enables smooth migration to Mifare card technology in existing Nedap XS, Nedap
AEOS and third party systems. The Convexs MN80 reads both Mifare and Nedap cards, the Convexs
M80 Mifare cards only. The Convexs output can be set to either Wiegand, XS RF modulation or
(encrypted) RS485 protocol. The Convexs MD80 reads Mifare DESFire cards.
Functionality and output is determined by the configuration of the Convexs reader. The configuration is
defined using the programm AEreco, and deployed by the configuration card or via AEmon. (More
information about configurations can be found in the Convexs_Invexs_InstallGuide_E.)
Three LED’s (red, green, blue) and beeper are included. The Convexs 80F can be flush mounted
(indoor / outdoor) in a electrical mounting box. Light (Gray) and Dark (Charcoal) fronts are available.
Dimensions: Convexs 80: 80 x 80 x 32 mm, Convexs 80F: 80 x 80 x 27 mm.
MOUNTING PROCEDURE CONVEXS
For mounting the Convexs the removable
backside must be placed on a wall. For removing
the backside of the Convexs gently push the two
lips at top and bottom towards the middle and
remove the backside. After the cable is
connected to the front (see ‘Connections’) the
front of the Convexs has to be clicked on the
backside.
MOUNTING PROCEDURE CONVEXS F
The Convexs F is opened by using the 2 small holes at the bottom and then
lifting the bottom side up. It can be mounted in a electrical mounting box.
Take care of the additional foam gasket and mounting direction (drain for
releasing eventually collected moisture must be on bottom side).
Attention: Don’t mount the Convexs F in a metal environment (Mifare
detection and Nedap AM detection can fail). For these applications use the
Convexs with the additional Protectors.
®