4. Convexs/Invexs connections
The Convexs/Invexs is not hot-swappable, so when making or changing connections be sure power is Off.
General:
- Check corresponding documentation of used AEpacks, Convexs converters and third party systems.
- Use correct shielded cables, cable shield must be connected to Power GND of Convexs (A2) Invexs (2)
and GND of external device (or metal case)
- Beeper can also optional be controlled by configuration settings (see chapter 5).
- Check for Invexs 190 cabling colours
4.1. Convexs Connections
4.2. Invexs 170 Connections
4.3. Invexs 190 Connections
Remark:
UL*,NA*, MD* and BEEP are Open Collector to GND.
If Convexs adapters (AX1014 or AB350) are used, the original UL and NA signals
of the reader are converted to be used with UL* and NA* of the Convexs/Invexs.
Invexs 190 to AX1014 or AB350 needs additional connection between GND (for UL and NA) and
Antenna GND on the AX1014 / AB350 (Invexs 190 has no separate cable for this connection)
Convexs Function
A1 Power /
XSMOD
Power in (10-30VDC) /
XS modulator (120kHz)
A2 POWER GND/shield
Power Ground
A3 A (-) RS485
A4
B (+)
RS485
A5 D0 Wiegand Data 0
A6
D1
Wiegand Data 1
A7 BEEP Beep input
A8
UL*
UL led input
A9 GND Led/Beep Common Ground
A10 NA* NA led input
Convexs
Rear view
Invexs Function
1 Power /
XSMOD
Power in (10-30VDC) /
XS modulator (120kHz)
2 POWER GND/Shield Power Ground
3 A (-) RS485
4 B (+) RS485
5 D0 Wiegand Data 0
6 D1 Wiegand Data 1
7 BEEP Beep input
8 UL* UL led input
9 GND Led/Beep Common Ground
10 NA* NA led input
1
10
1
10
5
1
6
1
Invexs
with display
Invexs
without display
Wire
Colour
Function
w1 Red Power in (10-30VDC) /
XS modulator (120kHz)
w2 Black Power Ground / RF Ground
w3 Grey RS485 A (-)
w4 Violet RS485 B (+)
w5 Green Wiegand Data 0 (D0)
w6 White Wiegand Data 1 (D1)
w7 Yellow Beep input (BEEP)
w8 Pink UL led input (UL*)
w9 Blue MD led input (MD*)
w10 Brown NA led input (NA*)
w11 Shield / Metal EM shield (connected to power ground)
Cable shield (wire 11) must
be
connected to the metal case of
the external device