User Manual

Page of 15 43 Manual FC-line
4 Executing the installation
When all the preparations are taken into account, the installation of the system can take place. The installation
consists of physically mounting the system in the right orientation, installing the cabling and applying power
to the system.
Physical installation: Wall mounting
The FC-line gates can be mounted in three different methods:
Mounted on the floor mount column (recommended)
Mounted on the front of the door frame
Mounted on the side of the door frame
Distance to the floor
The distance to the floor should be at least 200 mm / 8" to have enough space for cabling and filters.
Rotation of the antenna
The antenna can be rotated vertically to create the optimal focussed RF field. Please note that only
when both sensitive sides of the two antennas are facing each other, the maximum distance of 2200
mm / 7.2 ft can be obtained. When rotating the antenna, please make sure the Customer Counter
PCB's also face each other to work properly. The Customer Counter PCB can easily be rotated inside
the antenna.
Prevent interference
Using the floor mount column increases the performance of the FC-line gate. It prevents interference
from the door frame or wall behind the door frame. When mounting the FC-line gate to the door
frame, using the distance brackets included in the installation set, will help prevent interference.
Order floor mount column seperately
The floor mount column is not included in the product, but should be ordered separately, article
number 9216561.