Physical installation: Installing cabling and filters
During the preparation phase, the exact cabling required was already determined. Now these cables can be
placed.
All wiring should be done according to local regulations.
Model ASSY FL180R RF+MD antennas with internal Renos shall only be powered by the POE
Model PW-085C-1Y560HPOE provided by Nedap. There are four article numbers for the POE
model available, according to the country of origin. Each is packaged in a box with one of
these mains cord: EU, USA, China, UK and Swiss.
To disconnect the system from the mains, please remove the power cord either from the POE
unit or from the mains power socket.
When cables are installed, it is recommended to mark them with IN and OUT, or PREVIOUS and NEXT,
as this will allow you to distinguish them from each other.
Filters
Please note that filters should be placed around the cables to reduce interference with other systems. These
filters are delivered together with the system.
Filter should be placed at:
Every Power Inserter: around the Ethernet cable, both at the OUT and IN port.
Every Renos unit: around the Ethernet cable, both at the OUT and IN port.
Every 9 m / 30 ft. for longer Ethernet cables.
To save yourself a huge amount of frustration, please first place the filters attaching thebefore
connectors. The other way around is not possible. Many have tried before.