Connect Renos and Power Inserter
Power Inserter (not included, order separately)
ASSY FC180R RF
ASSY FC180R RF
Power Inserter - OUT
Renos - IN
Renos - OUT
Renos - IN
Power consumption Renos
When the installation location of the products is clear, the location of Power Inserters needs to be defined.
There is a maximum number of Renos units that can be connected to one Power Inserter, depending on which
technologies are used and the number of add-ons that are in use.
Technologies in
use
# units / Power Inserter -
230V
# units / Power Inserter -
115V
Index:
RF = Radio Frequency 8.2 MHz
MD = Metal Detection
2 SD's = 2 connected smart
deactivators
RF 6 5
RF + MD 4 4
RF + 2 SD's 5 4
RF + MD + 2 SD's 4 3
Please note that you can only use a Nedap Power Inserter (Power-over-Ethernet) to power Renos
systems. It is not possible to use generic Power-over-Ethernet switches or stand-alone inserters.