User's Manual

Page 7 of 9
3 Wiring diagram
Schematically diagrams below shows an example of the connections between used modules.
The picture shows the full configuration that can be built up.
Figure 2 Example full configuration
The connections for a full configuration are:
1 Mains Cable Power Adapter
Connects the Main power to the Power Adapter
2 DC power line
Connects 30VDC from the Power Adapter to the Electronics Unit [9922679, 9922822, 9922849 or
9922857]
3 Tx coax cable
Connects the Tx Output from the Electronics Unit EC-x to the Match PCB FL-AS or FL-AL.
(7829663/7831455) Cable is provided with filters. The cable carries the RF signal including a 30VDC
signal for lighting.
4 Rx coax cable
Connects the Rx Input from the Match PCB FL-AS or FL-AL 7829663/7831455 to the Electronics Unit
EC-x. Cable is provided with filters. The cable carries the RF signal including a 30VDC signal for
lighting.
5 Rx coax cable
Connects the Rx Output from the Electronics Unit EC-x to the Match PCB FL-AS/AL 7829663 or
7831455. Cable is provided with filters. The cable carries the RF signal including a 30VDC signal for
lighting.
6 Tx coax cable
Connects the Tx Input from the Match PCB FL-AS/AL 7829663 or 7831455 to the Electronics Unit EC-
x. Cable is provided with filters. The cable carries the RF signal including a 30VDC signal for lighting.
7 Grow Cable
Connects Electronics Unit to one of the Communication & Grow Units [9922628 or 9922636 or
9922644 or 9926402]. Carries 30VDC, Serial communication and inputs for CC Units AS/AL.