To save yourself a huge amount of frustration, please first place the filters attaching thebefore
connectors. The other way around is not possible. Many have tried before.
Filters can be ordered as spare part with Nedap. Please refer to the Nedap Retail Portal for more
information.
The filters that are close to a Renos unit should be placed inside the foot of the gate. If there are multiple
filters in the electronics are of the gate, they should be tied together.
Ethernet cables
Connect the Ethernet cable from the OUT port with the IN port of the next Renos unit
First, in all aisles connect the Ethernet OUT port with the IN port of the next Renos unit, always following the
directions of the arrows in the cabling indicated by the image below.
Please make sure to test every Ethernet cable for correct connections and twisting of all 4 pairs (8
wires) with an Ethernet cable tester. This is to make sure that the system can function correctly.
RFID coaxial cable
If the Ethernet cable is connected, connect the RFID coaxial cable in the same way. Connect from Gate 1 (next)
to Gate 2 (previous), from Gate 2 (next) to Gate 3 (previous), etc.
The RFID coaxial cables should be connected from the NEXT port of one reader, to the PREVIOUS port of the
second reader. PREVIOUS and NEXT are related to the order of units in relation to the first Power Inserter.