Please make sure that you don't make sharp bends in the RFID coaxial cable. This will have a
negative impact on the performance of the system.
Don't use a tool to tighten the RFID coaxial cable connectors. This is not necessary and might break
the connectors. If the connector is tightened by hand, that is good enough.
Status LEDs
The electronics inside the unit has several status LEDs that can be used to discover the status of each part of
the electronics.
Renos unit
Led Color Status Explanation
1 Green
On There is a Renos unit connected to the OUT port of this unit
Off
There is Renos unit connected to the OUT port of this unitno
2 Blue
Blinking
There is device connected to the OUT port of this unitno
On There is a Power Inserter connected to the OUT port of this unit
3 Red
On There is an issue with the power supply at the OUT port of this unit (too little current drawn)
Blinking There is an issue with the power supply at the OUT port of this unit (too much current drawn)
Off
There is issue with the power supply at the OUT port of this unitno