Connection OK
Take a look at the
PPP status: When PPP
is "3F" then data will
be send to the database
When data is send, PPP
status will be FF or BF
When the modem is
switching from
"0" > "-1" > "0" it is
starting to call out of
the store
Modem "2", starts
calling and is getting
"3"
Modem
-1 = No modem - Wrong cable / modem
switched off / wrong modem
0 = Modem found - default value
1 = Modem connected - someone is
connecting to the NCC
2 = Modem is trying to connect
3 = Connection present- NCC is connected
to the other side
Ppp = Point to Point Protocol
(when modem status is 3)
00 = No PPP - No modem connection / provider
does not understand the options
01 = LCP ISP is ready - NCC can not handle
the provider options
03 = LCP NCC is ready- Wrong name or Password
07 = PAP NCC is ready- Provider does not
understand IPCP options
0F = IPCP ISP is ready- NCC does not understand
IPCP options
1F = IPCP NCC is ready- TOP-server can not be
found / wrong IP-number and/or provider
does not support protocol
3F = TOP started- Default value
7F = TOP execute- Default value (very rare)
FF = Hangup- Default value (very rare)
Make a drawing of the
systemconfiguration
and mail / fax it to the
Nedap in Groenlo