SENSIT Installation Guide 2013-10-09 This information is furnished for guidance, and with no guarantee as to its accuracy or completeness; its publication conveys no license under any patent or other right, nor does the publisher assume liability for any consequence of its use; specifications and availability of goods mentioned in it are subject to change without notice; it is not to be reproduced in any way, in whole or in part, without the written consent of the publisher. © Nedap AVI, P.O.
SENSIT CONTENTS 1 2 3 4 5 6 7 A B C D INTRODUCTION ................................................................................................................................................................ 3 1.1 SENSIT IR ................................................................................................................................................................. 3 1.2 SENSIT Flush Mount..........................................................................................
SENSIT 1 INTRODUCTION The SENSIT vehicle detection system facilitates accurate measurement on occupancy of individual parking spaces in car parks, and on-street parking spaces. This information can be used to guide traffic to free parking spaces but can also be used for on-street parking enforcement and overstay detection. For on-street enforcement the number of occupied parking spaces can be compared with the number of payments realized by the pay station.
SENSIT 2 SENSIT IR 2.1 SAFETY PRECAUTIONS The following safety precautions should be observed during normal use, service and repair. • The SENSIT IR may only be installed and serviced by qualified service personnel. • To be sure of safety, do not modify or add anything to the SENSIT IR other than mentioned in this manual or indicated by NEDAP N.V. 2.2 DETECTION The SENSIT IR is featured with earthmagnetic field and infrared detection. 2.
SENSIT 2.4 INSTALLATION CONDITIONS The installation recommendation is based on the following environmental conditions; Ambient temperature between 5 to 40 °C [41 to 104 °F] - Dry weather conditions - Surface based on concrete, asphalt or pavement 2.5 REQUIRED INSTALLATION MATERIALS The following would be required for mounting of the SENSIT IR. - Equipment: Automatic drill - Drill size: Dimensions Ø 85 mm [3.35 in] - Drill depth: 54 mm [2.
SENSIT STEP 6 Drill a hole of 85 mm [3.35 in] into the centre of the parking bay. STEP 7 Apply the right amount of filler and pour into the hole. STEP 8 Double-check the node ID number and the parking bay on the installation plan and place the SENSIT IR into the hole. Take attention that you fixate the SENSIT during the curing time otherwise the SENSIT will start to float. STEP 9 After installation the SENSIT IR must be calibrated.
SENSIT Ensure to note the node ID number of the SENSIT IR to the parking bay. Update the parking bay configuration list in the SIM software to ensure the new sensor is linked to the right parking bay. Figure 3: Screenshot parking bay configuration © Nedap AVI, P.O.
SENSIT 3 SENSIT FLUSH MOUNT 3.1 SAFETY PRECAUTIONS The following safety precautions should be observed during normal use, service and repair. • The SENSIT Surface Mount may only be installed and serviced by qualified service personnel. • To be sure of safety, do not modify or add anything to the SENSIT Surface Mount other than mentioned in this manual or indicated by NEDAP N.V. 3.2 DETECTION The SENSIT Flush mount is featured with earth magnetic field detection. 3.
SENSIT We have good results with the rapid mortar TM 5R. See appendix B for specifications. Ensure to follow the guidelines and instructions as outlined on the filler material. 3.6 INSTALLATION PROCESS Installation process as described in paragraph 2.6, however with above mentioned drilling depth. 3.7 REPLACEMENT When the battery life of the SENSIT Flush Mount fails after specified life time, we advise to replace the unit completely.
SENSIT 4 SENSIT SURFACE MOUNT The SENSIT Surface Mount is designed for installations where the sensors cannot be drilled into the parking space (e.g. multi storey car parks and rooftop parkings) or existing car parks. 4.1 SAFETY PRECAUTIONS The following safety precautions should be observed during normal use, service and repair. • The SENSIT Surface Mount may only be installed and serviced by qualified service personnel.
SENSIT Figure 7: Top laser engraved side of the SENSIT Surface Mount The node ID is mentioned on the top of the housing under ID. There is also a 125kHz passive RFID label embedded into the SENSIT Surface Mount. This can be used for verification of the SENSIT or to localize the SENSIT on the parking lot. © Nedap AVI, P.O.
SENSIT 4.
SENSIT 4.7 INSTALLATION PROCESS Follow the recommended installation procedure for the SENSIT Surface Mount as described below. STEP 1 Clean the location where the sensor should be mounted STEP2 Indicate where the sensor should be positioned. Distribute the SENSIT Surface Mount over the empty parking lot (without mounting them into the floor). STEP 3 All SENSIT Surface Mount are set to transport/stock mode during shipment.
SENSIT STEP 6 Pour the filler into the mounting ring of the SENSIT Surface Mount. A pneumatic kit dispenser makes it easy to apply the glue into the mounting ring. For good fixture with the surface please fill the entire mounting ring. Note: Ensure excessive glue is removed from the bottom black core part of the unit, as this will make it very difficult to replace the core part. Note: For non permanent mounting only glue the ring with a few dots of glue.
SENSIT STEP 11 After installation the SENSIT IR must be calibrated. Ensure that the parking space is empty and that there is no car parked on top of the sensor or on neighbouring parking bays. Also ensure not metal parts (such as tools) are positioned in the surrounding of the sensors as this might affect calibration. See InstallGuide SIM Software for more information on calibration. Note: When the SENSIT Surface Mount are not calibrated they hardly send any messages.
SENSIT STEP 4: After installation the SENSIT Surface Mount must be calibrated. Ensure that the parking space is empty and that there is no car parked on top of the sensor or on neighbouring parking bays. STEP 5: Ensure to note the node ID number of the SENSIT Surface Mount to the parking bay and update the parking bay configuration list in the SIM software, see paragraph 2.7. © Nedap AVI, P.O.
SENSIT 5 PROJECT SUPPORT Based on our thorough project analysis including configuration and installation advice we can offer the customer the best AVI solution. 5.1 SITE SURVEY & INSTALLATION ADVICE This will consist of an engineer visiting the site to visually inspect and analyze the location. We will then carry out calculations and provide you with detailed configuration and installation advice for the equipment for a specific project. 5.
SENSIT 6 FCC AND IC DECLARATION 6.1 Compliance statements (part15.19) This device complies with part 15 of the FCC Rules and to RSS210 of Industry Canada. Operating is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. Cet appareil se conforme aux normes RSS 210 exemptés de license du Industry Canada.
SENSIT 7 TECHNICAL SPECIFICATIONS Technical info SENSIT IR SENSIT Surface Mount SENSIT Flush Mount 868 MHz (Europe) 868 MHz (Europe) 868 MHz (Europe) 902 – 928 MHz (US) 902 – 928 MHz (US) 902 – 928 MHz (US) 915 – 928 MHz (AUS) 915 – 928 MHz (AUS) 915 – 928 MHz (AUS) Detection Magnetic and IR Magnetic and IR Magnetic Detection accuracy 98% 98% 95% Mounting Into the floor Glued onto the floor Into the floor, flush with the surface Snowplough resistant No No Yes Load resistance H
SENSIT A PART NUMBERS SENSIT Vehicle Detection sensors SENSIT IR EU yellow SENSIT IR US yellow SENSIT IR AU yellow part number: SENSIT IR EU black SENSIT IR US black SENSIT IR AU black part number: SENSIT Flush Mount EU black SENSIT Flush Mount US black SENSIT Flush Mount AU black part number: SENSIT Flush Mount EU yellow SENSIT Flush Mount US yellow SENSIT Flush Mount AU yellow part number: SENSIT Surface Mount EU SENSIT Surface Mount US SENSIT Surface Mount AU part number: part number: 995852
SENSIT B RAPID MORTAR © Nedap AVI, P.O.
SENSIT C Modified Silicon Polymer Sabatack Fast ultra-fastbonding Description Sabatack Fast is an ultra fast-acting 2-component, elastic, humidity-curing, MS polymer-based construction adhesive. Its primary use is bonding with fast hardening, handling after only 2 hours, which makes this product excellent for use in mass production.Sabatack Fast has a medium viscosity and a high modulus elasticity.
SENSIT D POLYURETHAN P E R M A P U R® 2 6 5 4 A / B Universal Polyurethane liquid adhesive PERMAPUR® 2654 A/B consists of two components A-component (Polyol) and a B-component (Isocyanate). The resin is supplied in a bi-pack. PERMAPUR 2654 A/B is used as an universal polyurethane resin which can be applied by pouring the fluid. The system is insensitive to moist and shows no blistering and is therefore less critical in processing.