User Manual

5 Specifications SMART DEAC
Enviromental
Description
Material Construction Aluminium
Protection Class IP20
Min. Typical Max. Condition
Operating frequency 7.5 MHz 8.2 8.8 MHz
Operational
temperature
0°C 40 °C
Storage temperature -10°C +70°C
Relative Humidity 20% 90% non-condensing
Operating Distance 0.3m Antenna type dependant, Tag dependant
Input Requirements and electrical specifications
Description Min. Typical Max. Condition
Input Voltage 90VAC 100-240 264VAC Full Range; 50/60Hz
Input Current 0.35A - 0.7A 264VAC - 90VAC
Line Frequency 47 Hz 50-60Hz 63Hz -
Inrush Current @25°C 230VAC Cold Start
Operation Voltage 11.64VDC 12VDC 12.6VDC
Power 6W 230VAC 50Hz
Regulations
Safety approvals of the Power Adapter:
· cULus according to UL/CSA 60950-1
· CB according to IEC60950-1
· TUV EN60950-1 (2006)
· NEC Class 2 according to UL1310
· CE Europe according to EN60950-1
· Japan PSE
Telecom system approval
· Cannada IC ID according to RSS210 IC ID:1444A-SMARTDEAC
· US according to FCC Part 15 FCC ID:CGDSMARTDEAC
· CE according to EN300330
· Japan pending
In compliance with Human exposure assessment according to:
· EN62369-1 and EN50364
· ICNIRP Guidelines
· IEEE C95.1
· RSS102
· ARIB STD-38
· IEC62369-1
Electromagnetic compatibility
· EN 301 489 (Emission according to EN55022)
· IEC 61000-6-2
· IEC 61000-6-3
· CISPR 22
9
16-manual smart deac cgdsmartdeac.doc | Nedap Retail Support