Data Sheet

Table Of Contents
Install the windshield tag horizontal on the inside of the windshield. For more
Read lobe characteristics
Application note uPASS Reach
This application note describes the installation of the uPASS Reach reader for parking entry control applications. The uPASS Reach can
identify an AVI tag from distances up to max. 4 meters [12 ft].
Ensure the tag is positioned on the same side of the windshield as the reader
Present the tag in line-of-sight to the reader.
This document is based on a windshield angle of 45°. Tilt the reader with a
Parking
uPASS Reach installed on a pole
at the barrier.
Figure 2: uPASS Reach pole mounting, uPASS Reach
installed at ° degrees anglea 45
4
5°
a
ng
l
e
Example of a windshield tag
is located.
45 ° facing the windshield to ensure optimal alignment between reader and tag.
Onto a pole, located directly behind the barrier, using the pole mounting kit (7591152).
Installation height between 1,20 and max. 2 meters from ground level.
Use of windshield mounted tags
Position reader;
1
2
3
Item
Parameters
Description
Between 1.20 and max 2 meters [6 ft]
above driving lane ground level
Mounting height
Mounting position
Frequency setting
Onto a pole directly mounted behind the barrier
Standard frequency, in case of multi-lane
application, use frequency offset.
Figure 1: detection angle 45 degrees
information see the Windshield Tag Installsheet.
Tilt the reader with a 45 facing the windshield to ensure optimal alignment °
between reader and tag.

Summary of content (2 pages)