5 Specifications X2.
Enviromental
Description PG27 PG27 PG39 FL30 FL45 W37-CC EQ45-F
Antenna Hight (in mm) 1533 1670 1665 1665 1500 1800
Antenna With (in mm) 273 390 322 462 370 700
Antenna Base (in mm) 104 104 100 100 55
Frame thickness (in mm) 20 20 70 70 40 67
Weight (in kg) 13 20 12 15 8 10
Material Construction PMMA* PMMA Al** Al**
Al**
Copper Polycarbonate
Material Covers Stainles Steel
Stainless
Steel
ABS*** HI-121,
Stainless
Steel Eternit Calibre 201-15
Protection Class IP20
*PMMA= Polymethylmethacrylaat **AL=Aluminum ***ABS= Acrylonitril-butadieen-styreen
Description
Min. Typical Max. Condition
Operating frequency 7.4 MHz 8.8 MHz
Operational temperature 0°C 40 °C
Storage temperature -10°C +70°C
Relative Humidity 20% 90% non-condensing
Operating Distance 0.9m 2.4m
Tag and Antenna dependant
see Section 2
Input Requirements and electrical specifications
Description Min. Typical Max. Condition
Input Voltage 100VAC 240VAC Full Range; 50/60Hz
Input Current - - 2A 90VAC 50Hz
Line Frequency 47 Hz 50-60Hz 63Hz -
Inrush Current @25°C 60A 230VAC Cold Start
Operation Voltage 29.1VDC 30VDC 30.9VDC
Power 0 W 30W 230VAC 50Hz
Regulations
Safety approvals of the Power Adapter:
· cULus according to UL/CSA 60950-1
· Japan PSE
· CE Europe according to EN60950-1
Telecom system approval
· Canada IC ID according to RSS210 IC ID: 1444A-
· US according to FCC Part 15 FCC ID: CGD
· CE according to EN 300 330
In compliance with Human exposure assessment according to:
· EN62369-1 and EN50364
· ICNIRP Guidelines
· IEEE C95.1
· RSS102
· ARIB STD-38
Electromagnetic compatibility
· EN 301 489
· IEC 61000-6-2
· IEC 61000-6-3
· CISPR 22 / EN55022