Operating modes
This appliance can be used in exhaust-air mode or
circulating-air mode.
Exhaust air mode
Note: The exhaust air must not be conveyed into a
functioning smoke or exhaust gas flue or into a shaft
which is used to ventilate installation rooms which
contain heat-producing appliances.
■ Before conveying the exhaust air into a non-
functioning smoke or exhaust gas flue, obtain the
consent of the heating engineer responsible.
■ If the exhaust air is conveyed through the outer wall,
a telescopic wall box should be used.
Circulating-air mode
Note: To bind odours in circulating-air mode, you must
install an activated carbon filter. The different options for
operating the appliance in circulating-air mode can be
found in the brochure. Alternatively, ask your dealer.
The required accessories are available from specialist
outlets, from customer service or from the Online Shop.
KBefore using for the first
time
Before using for the first time
Please read the following information before using the
appliance for the first time:
Clean the appliance and all accessory parts thoroughly.
Before you can use your new appliance, you must apply
certain settings.
Initial use
Note: When it is delivered, the appliance is preset to air
recirculation mode.
Possible settings:
■ In air recirculation mode, if ’‚ˆ is displayed, the
value ‹ (factory setting) is set.
■ In air extraction mode, if ’‚ˆ is displayed, the value
‚ is set.
Switching over the display for exhaust air mode
For air extraction mode, the electronic controller's
display must be switched accordingly to the basic
settings.
1. Check whether the appliance is connected and
switched off.
2. Switch on the appliance.
3. Within the next 10 seconds, press and hold the
. symbol for approximately four seconds.
The first four displays provide product information.
Turn the twist knob to view the individual displays.
4. Touch the . symbol again to access the basic
settings.
™‚ and ‹ light up as a presetting in the displays.
5. Touch the . symbol repeatedly until ™‚ˆ is
displayed.
The air which is drawn in is cleaned
by the grease filters and conveyed to
the exterior by a pipe system.
The air which is drawn in is cleaned by the
grease filters and an activated carbon filter
and conveyed back into the kitchen.
Product information Display screen
After-sales service index (ASSI)
‹‚
Production number
”š
Production number 1
І.
Production number 2
‹.†