NOTE
When the PIR is being restored factory settings, please make sure power source is
connected.
Battery Usage Tips
Battery life of the contact sensor is approximately 1 years at factory default settings.
The current battery level is displayed in the gateway. Red battery icon means the
battery needs replaced. In order to avoid tamper detection, while replacing the battery,
please disconnect the association of the contact sensor with other devices.
Note
Contact sensor is battery powered. Using batteries other than specified may result in
explosion. Dispose of properly, please observe environmental protection rules.
Advanced Configuration
The following information is for someone that has some experience in setting up a Z
Wave system or someone that has computer software running a Z
Wave controller
or Z
Wave Gateway. Please get familiar with software of Z
Wave controller or Z
Wave Gateway before getting started.
1. Sensitivity Level Setting
This parameter defines the sensitivity of PIR detector, it is recommended to test the
detector with movements from a farthest end of the coverage area at first time of use.
If movements cannot be detected sensitively, simply adjust the sensitivity level with
this parameter. This Parameter can be configured with the value of 8 through 255,
where 8 means high sensitivity and 255 means lowest sensitivity.
Function: Sensitivity Level Setting.
Parameter Number: 1.
Parameter Size: 1 Byte.
Available Settings
8 ~ 255.
Default Setting: 12.
2. On/Off Duration
This parameter can be determined how long the associated devices should stay ON
status. For instance, this parameter is set to 30(second), the PIR detector will send a
BASIC_SET Command to an associated device with value basic set level if PIR
detector is triggered and the associated device will be turned on 30(second) before it
is turned off. This Parameter value must be large than Parameter 6#. If user set this
parameter to default by Configure CC, the parameter #6 will be set to default value.
Function: On/Off Duration Setting