Instruction Manual
Parameter Number: 2
Parameter Size: 2Byte
Available Settings
:
5 ~ 600(second)
Default Setting: 30
3. Basic Set Level
Basic Set Command will be sent where contains a value when PIR detector is
triggered, the receiver will take it for consideration; for instance, if a lamp module is
received the Basic Set Command of which value is decisive as to how bright of dim
level of lamp module shall be. This Parameter is used to some associated devices.
Function: Basic Set Level
Parameter Number: 3
Parameter Size: 1 Byte
Available Settings
:
0, 1 ~ 99 or 255
0 – OFF, Alarm cancelling or turning a device off
1 ~ 99 or 255 – ON (Binary Switch Device)
Dim Level (Multilevel Switch Device)
Default Setting: 255
4. PIR Detecting Function Enabled/Disabled
This parameter can be enabled or disabled the PIR detector detecting function.
Function: Enabled/Disabled PIR Function
Parameter Number: 4
Parameter Size: 1 Byte
Available Settings
:
0 or 255
0 – Disable PIR Detector Function
255 – Enable PIR Detector Function
Default Setting: 255
5. Ambient illumination Lux Level
This parameter can be set a lux level value which determines when the light sensor is
activated. If the ambient illumination level falls below this value and a person moves
across or within the detected area , PIR detector will send a Z
‐
Wave ON command
(i.e. BASIC_SET (value = parameter3) to an associated device and activate it.
Function: Lux Level Set
Parameter Number: 5
Parameter Size: 2 Byte
Available Settings
:
0 ~ 1000(Lux)
Default Setting: 100(Lux)
6. Re
‐
trigger Interval Setting
This Parameter can be used to adjust the interval of being re
‐
triggered after the PIR
detector has been triggered. This Parameter value must be less than Parameter 2#. If
user set this parameter to default by Configure CC, the parameter #2 will be set to