Instruction Manual
default value.
Function: Re
‐
trigger Interval Setting.
Parameter Number: 6
Parameter Size: 1 Byte
Available Settings
:
1 ~ 8(s)
Default Setting: 8
7. Light Sensor Polling Interval
This Parameter can be set the light sensor measure ambient illumination level interval
time.
NOTE: This Value Must Be less than Wakeup Interval Time.
Function: Light Sensor Polling Interval
Parameter Number: 7
Parameter Size: 2 Byte
Available Settings
:
60 ~ 36000(second)
Default Setting: 180(s)
8. Lux Level Function Enable
If this parameter is set to ‘1’, and when Lux level less than the value define by
parameter #5, PIR detector will send a BASIC_SET command frame(i.e. BASIC_SET
(value = parameter 3) to an associated device and activate it. If Lux Level greater than
the value define by parameter #5, PIR detector will not send a BASIC_SET command
frame.
Function: Lux Level Enable
Parameter Number: 8
Parameter Size: 1 Byte
Available Settings
:
0, 1
Default Setting: 0
9. Ambient illumination Lux Level Report
This parameter defines by how much Lux Level must change, in lux, to be reported to
the main controller.
Function: Lux Level Report
Parameter Number: 9
Parameter Size: 1 Byte
Available Settings
:
0 ~ 255(Lux)
Default Setting: 100(Lux)
10. Ambient Temperature Differential Report
This parameter is configured the value that differential between current measured and
previous
report value. If the differential value larger than the settings, device will report this
measured
temperature value to nodes associated in lifeline.