Instruction Manual
Differential Value = [Value] × 0.1℃
Function: Temperature Report
Parameter Number: 10
Parameter Size: 1 Byte
Available Settings
:
0 ~ 127
Default Setting: 5
11. Led Blink Enable
This parameter defines the Led on/off enable. If this parameter is set to ‘1’, the led
blink will be enabled, the led will blink once when motion sensor detect a movement.
Otherwise, the led will be turned off always.
Function: Led Blink Enable
Parameter Number: 10
Parameter Size: 1 Byte
Available Settings
:
0, 1
Default Setting: 1
12. Motion Event Report One Time Enable
‘1’ – The motion detected event will be sent to controller only once until device report
motion cleared event.
‘0’ – The motion detected event will be sent to controller when device detects a
movement event.
Function: Motion Event Report One Time Enable
Parameter Number: 11
Parameter Size: 1 Byte
Available Settings
:
0, 1
Default Setting: 1
99. Ambient light intensity calibration
This parameter defines the calibrated scale for ambient light intensity. Because the
method and position that the sensor mounted and the cover of sensor will bring
measurement error, user can get more real light intensity by this parameter setting.
User should run the steps as blows for calibrating
1) Set this parameter value to default(Assumes the sensor has been added in a Z
‐
Wave Network).
2) Place a digital luxmeter close to sensor and keep the same direction, monitor the
light intensity value (Vm) which report to controller and record it. The same time user
should record the value (Vs) of luxmeter.
3) The scale calibration formula: k = Vm / Vs.
4) The value of k is then multiplied by 1000 and rounded to the nearest whole
number.
5) Set the value getting in 5) to this parameter, calibrate finished.
For example, Vm = 300, Vs = 2000, then
k = 300 / 2600 = 0.11538