Instruction Manual
Including Sensor (PIR) to Z-wave Network
The PIR can be included to the Z-wave network by pressing on the code button.
1) Disassemble the PIR main body and insert the battery into the contact sensor. Make
sure the device is located within the direct range of the controller.
2) Set the controller into the learning mode (see mail controller’s operating manual).
3) Quickly, triple click the code button, LED light will flash red for 5 times.
4) PIT will be detected and included in the Z-wave network.
5) Wait for the main controller to configure the PIR.
Excluding Sensor (PIR) from Z-wave Network
1) Make sure the sensor is connected to power source.
2) Set the main controller into the learning mode (see main controller’s operating
manual).
3) Quickly, triple click the code button, LED light will flash red for 5 times.
4) Wait for the main controller to delete the sensor.
Restore PIR to Factory Default Settings
Reset procedure will delete all information on the Z‐Wave network and Z‐Wave
controller or Z‐Wave Gateway, and restore the sensor to factory default settings.
1. Remove the device cover.
2. Make sure the sensor is powered.
3. Press and hold the button for 10 seconds,LED will blink 5 times.
4. Release the button.
Installation Steps
Holder Installation
Battery Installation
Fix PIR on the holder
Holder Installation
Option One Option Two
Fix the holder with screws and screw stopper Fix the holder with double-sided
adhesive