Command
NOTIFICATION_REPORT
Type
HOME_SECURITY (0x07)
Event
Cover Removed
TAMPERING_COVERING_REMOVED(0x08)
Cover Closed
HOME_SECURITY_NO_EVENT (0x00)
Multilevel Sensor Report
This device embeds in a digital light sensor and a digital temperature sensor. The device measures
the ambient light intensity and temperature with a certain time interval that decides by
Configuration No. 17.
Light Sensor
When the ambient light intensity differential over 50lux (in default, and decides by Configuration
No. 11), the device will unsolicited to send a “SENSOR_MULTILEVEL_REPORT” to nodes which
associated in lifeline.
Command Class
COMMAND_CLASS_SENSOR_MULTILEVEL
Command
SENSOR_MULTILEVEL_REPORT
Type
Luminance
Scale
Lux
Temperature Sensor
When the ambient temperature differential over 1 (in default, and decides by Configuration No.
9), the device will unsolicited to send a “SENSOR_MULTILEVEL_REPORT” to nodes which associated
in lifeline.
Command Class
COMMAND_CLASS_SENSOR_MULTILEVEL
Command
SENSOR_MULTILEVEL_REPORT
Type
Air Temperature
Scale
Fahrenheit(US) / Celsius(Other Region)
Humidity Sensor
When the ambient humidity differential over 2RH% (in default, and decides by Configuration No.
10), the device will unsolicited to send a “SENSOR_MULTILEVEL_REPORT” to nodes which
associated in lifeline.
Command Class
COMMAND_CLASS_SENSOR_MULTILEVEL
Command
SENSOR_MULTILEVEL_REPORT
Type
Humidity
Scale
RH%