6) Motion Sensitivity
This parameter is configured the sensitivity that motion detect. This value is larger, the sensitivity is
lower, and the distance for motion detecting is closer.
Parameter Number
Size (Byte)
Available Settings
Default value
6
1
0 ~ 15
2
7) Temperature Offset Value
The current measuring temperature value can be add and minus a value by this setting.
Temperature Offset Value = [Value] × 0.1 Degree Celsius / Fahrenheit (US).
Parameter Number
Size (Byte)
Available Settings
Default value
7
1
-120 ~ 120
0
8) Humidity Offset Value
The current measuring humidity value can be add and minus a value by this setting.
Humidity Offset Value = [Value] × 0.1 RH%.
Parameter Number
Size (Byte)
Available Settings
Default value
8
1
-120 ~ 120
0
9) Temperature D-Value Setting
This configuration sets the changed value of the temperature. When the difference from the last
report exceeds this setting value, the device will report current temperature value to Z-Wave Hubs.
The D-Value = [Value] × 0.1 Degree Celsius / Fahrenheit (US).
Parameter Number
Size (Byte)
Available Settings
Default value
9
1
0 ~ 100
10
10) Humidity D-Value Setting
This configuration sets the changed value of the humidity. When the difference from the last report
exceeds this setting value, the device will report current humidity value to Z-Wave Hubs.
The D- Value = [Value] × 0.1 RH%.
Parameter Number
Size (Byte)
Available Settings
Default value
10
1
0 ~ 100
20
11) Luminance D-Value Setting
This configuration sets the changed value of the luminance. When the difference from the last report
exceeds this setting value, the device will report current luminance value to Z-Wave Hubs. Unit: Lux.
Parameter Number
Size (Byte)
Available Settings
Default value
11
1
0 ~ 120
50
12) Basic Set Level
This parameter is configured the value that BASIC_SET for nodes that associated in Group 2.
‘100’ BASIC_SET = 0xFF (ON).
‘0’ BASIC_SET = 0x00 (OFF).
Parameter Number
Size (Byte)
Available Settings
Default value
12
1
0 - 100
100