User's Manual

1When sensor enters to measure mode, this setting decides the Led indicated or not. 0’ No led blinks.
1’ led blinks with red.
Parameter Number
Size (Byte)
Available Settings
Default value
1
1
0, 1
1
2) OTA Led Disable
When OTA is running, this setting decides the Led blinking or not.
0’ No Led blinks.
1’ Led blinks with yellow.
Parameter Number
Size (Byte)
Available Settings
Default value
2
1
0, 1
1
3) Temperature Offset Value
The current measuring temperature value can be add and minus a value by this setting.
Temperature Offset Value = [Value] × 0.1 Degree Celsius / Fahrenheit (US).
Parameter Number
Size (Byte)
Available Settings
Default value
3
1
-120 ~ 120
0
4) Humidity Offset Value
The current measuring humidity value can be add and minus a value by this setting.
Humidity Offset Value = [Value] × 0.1 RH%.
Parameter Number
Size (Byte)
Available Settings
Default value
4
1
-120 ~ 120
0
5) Temperature D-Value Setting
This configuration setsthe changed value of the temperature. When the difference from the last
report exceeds this setting value, the device will report current temperature value to Z-Wave Hubs.
The D- Value = [Value] × 0.1 Degree Celsius / Fahrenheit (US).
Parameter Number
Size (Byte)
Available Settings
Default value
5
1
0 ~ 100
10
6) Humidity D-Value Setting
This configuration setsthe changed value of the humidity. When the difference from the last
report exceeds this setting value, the device will report current humidity value to Z-Wave Hubs.
The D- Value = [Value] × 0.1 RH%.
Parameter Number
Size (Byte)
Available Settings
Default value (min)
6
1
0 ~ 100
20
7) Low Temperature Alarm Value
This parameter is configured the threshold value that alarm level for low temperature. When the
current ambient temperature value is less than this configuration value,device will trigger an
alarm through the device associated in group 2.
The Alarm Value = [Value] × 0.1 Degree Celsius / Fahrenheit (US).
Parameter Number
Size (Byte)
Available Settings
Default value
7
2
-200 ~ 600
180
8) HighTemperature Alarm Value
This parameter is configured the threshold value that alarm level for High temperature. When the
current ambient temperature value is large than this configuration value, device will trigger an