User Guide
8233D PRO-EN
10
Note:
● The test lead can add 0.1Ω to 0.2Ω of error to resistance
measurement. To obtain precision reading in low-resistance
measurement, that is the range of 200.0Ω, short the input terminal
before measuring. In this time, the contact resistance displayed on the
LCD. You can subtract the contact resistance value from the measured
value.
● For high-resistance measurement (>10MΩ), it is normal taking several
second to obtain stable reading.
● The LCD display “OL” indicating open-circuit for the tested resistor or
the resistor value is higher than the maximum range of the meter.
5-3. Diode/Continuity check
5.3.1. Diode
① Set the rotary switch to “ ” position. First time, default mode is
diode check mode. You can enter the continuity check mode by the
“ FUNC” Key.
② insert the red test lead into the “VΩ” terminal and the black test lead
into the “COM” terminal.
③ Use the diode test mode to check diodes, transistors and other
semiconductor device. In the diode test mode sends a current through
the semiconductor junction, and the measure the voltage drop across the
junction. A good silicon junction drop between 0.5V and 0.8V.
④ For forward voltage drop reading on any semiconductor component,
place the red test lead on the component anode and place the black test
lead on the component cathode. The measured value show on the
display.
⑤ Reverse the test lead and measure the voltage across the diode again.
● If diode is good, the display shows “OL”.