User Manual
9999counts Handheld multimeter
14/15
2-3-10. Temperature measurement (°C/°F)
The operation is as follows: (above right figure)
1 Rotate the dial to the "TEMP" position;
2. Insert the two input ends of the temperature probe into the red table pen respectively
"V/Ω/Hz" and "COM" terminals, test probe inductive plug.
When measuring water, the temperature of the measured water will be displayed on the LCD.
3. Press the SELECT key to switch between Celsius degree and Fahrenheit degree (°C/°F).
2-3-13.NCV measurement
The operation is as follows: (lower right figure)
1、Rotate the dial to the "NCV" position (LCD displays "EF" in the absence of measurement);
2、The instrument has the NCV test point at its front end. As long as the point is close to
the AC voltage, the buzzer will emit different continuous sounds according to the signal's
different intensity. At the same time, the LCD will also display different segments according
to the strength of the signal.
Accuracy
Range
9999counts
Resolution
(-20-1000 )℃
±(1.0%+5)<400℃
±(1.5%+15)≥400℃
1℃
(0-1832 )℉
±(0.75%+5)<750℉
±(1.5%+15)≥750℉
1℉