User Manual
9999counts Handheld multimeter
6/15
2-3-2.AC current(ACV)
Accuracy
Range
9999counts
Resolution
100mV
±(0.8%+3)
0.01mV
1V
0.1mV
10V
0.001V
100V
0.01V
750V
±(1.2%+10)
0.1V
Input impedance:10MΩ;Standard sine wave and triangular wave
frequency response is 40Hz-1kHz;Other wave forms are: 40Hz-200Hz.
The specific operation is as follows: as shown on the right
1、Insert the black test lead into the "COM" socket while the red test
lead into the "V /Ω/ Hz" jack.
2、Turn the range switch to“ ”, to display the AC voltage
auto measurement mode.
Note:
1)、Before test there exits some residual numbers in the range, but does not
affect the measurement accuracy;
2)、 Do not input voltage exceed 750Vrms, if do, there will damage the instrument circuit;
3)、 When measuring high voltage circuit, pay special attention to avoid electric shock;
4)、After completing all the measuring operations, disconnect the test leads from the circuit under test.
V