operation manual

10
- GB -
Installation and connection
B, C
The unit can be placed submerged or dry.
For installation above water: Ensure a safety distance of at least 50 cm from combustible material. Fire hazard:
Do not cover the unit!
Install the transformer at a minimum safety distance of 2 m from the water.
8.
0.
How to proceed:
1. Position the unit such that it does not present a hazard to anyone and the lamps are tilted as desired.
2. Connect the plug of the spotlight connection cable to the socket on the transformer and hand-tighten the union nut.
Start-up
Attention! Sensitive electrical components.
Possible consequence: The unit will be destroyed.
Protective measure: Do not connect the unit to a dimmable power supply.
Attention! Dangerous electrical voltage.
Possible consequences: Death or severe injury.
Protective measures:
Electrical units and installations with a rated voltage of U > 12 V AC or U >30 V DC located in the water:
Isolate the units and installations (switch off and disconnect from the power supply) before reaching into the
water.
Isolate the unit before starting any work.
Secure the unit to prevent unintentional switching on.
Switching on: Insert the power plug of the transformer into the socket.
Check the function of the spotlights.
Switching off: Disconnect the transformer power plug.
Remedy of faults
Malfunction Cause Remedy
Power supply interrupted Check power supply Lamp does not light up
Bulb defective Replace bulb
Lamp glass soiled Clean Luminosity decreases
The brightness of the bulb reduces as the
operating time increases
Replace bulb
Water inside the spotlight housing Seal defective Check sealing rings and replace, if necessary
S