Maintaining and Repairing the Neptune Handheld System
9-18 N_SIGHT R900 User’s Manual for the Neptune Handheld System
During the calibration process, the Power key is disabled
temporarily and the backlight is turned up to 100%.
4. To stop the calibration process, tap Start | Settings |
System |
Power | Calibration | Stop Calibration.
Refer to Table 9.1 for possible error messages that can occur during
calibration.
Notification LEDs
At the top of the Nomad are two LEDs that provide status information.
The LED states are shown in the following table.
It takes up to 24 hours to complete the calibration. When finished, a notification
message states that the calibration is complete. Neptune recommends not using your
unit during the calibration process.
Table 9.1 Calibration Error Messages
Error Message Part Solution
Battery is not charging,
aborting
Battery temperature may be out of range.
W
ait until battery temperature settles and try
again.
Discharge became
invalid, restarting
Calibra
tion will restart itself.
AC power is in an
unknown or uncontrolled
state; aborting
Plug in unit and restart calibration. Try a
dif
ferent power supply and restart
calibration. If it continues to fail, have the
unit serviced.
Table 9.2 Calibration Error Messages
Right LED Function
Off On battery power
Solid yellow Charging on power supply
Solid green Fully charged on power supply