User Manual
Table Of Contents
- 13-0249- Exhibit Cover.pdf
- UPDATED_Pilot Release_Handheld System 11 13.pdf
- Neptune Handheld System User’s Manual
- 1 Introduction
- 2 Overview of the Neptune Handheld System
- 3 Using the CE5320 Handheld
- 4 Using the Nomad Handheld
- 5 Setting Up the R900 Belt Clip Receiver
- R900 Belt Clip Receiver
- Nomad Handheld and R900 Belt Clip Receiver
- Unpacking and Inspecting Equipment
- Using the R900 Belt Clip Receiver
- Using the R900 Belt Clip Receiver to Read a Route
- Updating R900 Belt Clip Receiver Firmware
- 6 Gathering Route Data
- The Reading Entry Screen
- Manually Collecting Meter Readings
- Collecting RR Readings
- Working with Accounts
- Validating Readings
- Removing a Reading
- Clearing a Skip Code
- Clearing a Comment Code, Customer Note, or Trouble Code
- Adding a New Meter to a Route
- Correcting or Changing Meter Information
- Finding and Displaying Reading-Entry Screens
- Resequencing Routes
- 7 Communicating with the Host Computer
- 8 Using the Field Programmer
- Connecting the Mouse
- Starting Field Programmer
- Programming the ProRead
- Querying the ProRead
- Reading the ProRead Register
- Programming the R900G Endpoint
- Using Command Gas
- Reading the R900G Endpoint Register
- Networking Two Registers
- Managing Formats
- 9 Maintaining and Repairing the Neptune Handheld System
- 10 Troubleshooting
- Appendix A Changing Volume Settings
- Appendix B Tokens List for Custom Format Screen
- Appendix C Pressure Configuration Factor Indexes
- Glossary
- Index
N_SIGHT R900 User’s Manual for the Neptune Handheld System C-1
R900G: 12750-000
Appendix C Pressure Configuration Factor Indexes
Available Formats
The following table is used for selecting gas formats available from
American Meter, Sensus, and Actaris when using the Field Programmer.
Table C.1 Pressure Configuration Factor Index Table
Index Part
Number Drive
Gauge
Pressure
Atmospheric
Pressure
Base
Pressure
Actual Gear
Ratio
Pressure
Compensation
Factor
American Meter - AL/AR/AC/AM/AT
175/210/250/350/425/630
52180G066
1 ft
3
2 psig 14.40 14.73 900 1.111111
28538G151
1 ft
3
2 psig 14.73 14.73 883.333333 1.132075
52180G067
2 ft
3
2 psig 14.40 14.73 450 1.111111
04972G116
2 ft
3
2 psig 14.73 14.91 443.055556 1.128527
04972G122
2 ft
3
2 psig 14.40 14.65 445.454545 1.122449
04972G118
2 ft
3
2 psig 14.73 14.73 442.000000 1.131222
04972G124
2 ft
3
2 psig 14.55 14.73 443.055556 1.128527
04972G120
2 ft
3
5 psig 14.40 14.73 381.944444 1.309091
04972G117
2 ft
3
5 psig 14.73 14.91 376.125000 1.329345
04972G119
2 ft
3
5 psig 14.73 14.73 374.305556 1.335807
04972G127
2 ft
3
5 psig 14.40 14.65 376.125000 1.329345
04972G121
2 ft
3
10 psig 14.40 14.73 303.333333 1.648352
Sensus/Equimeter - R-275 / R-315:
001-63-537-48
2 ft
3
2 psig 14.40 14.73 445.867 1.121411
001-63-537-41
2 ft
3
5 psig 14.40 14.73 379.911 1.316098
001-63-537-49
2 ft
3
10 psig 14.40 14.73 300.781 1.662339
Sensus/Equimeter - # 415:
001-41-537-48
2 ft
3
2 psig 14.40 14.73 445.867 1.121411
001-41-537-41
2 ft
3
5 psig 14.40 14.73 379.911 1.316098
001-41-537-49
2 ft
3
10 psig 14.40 14.73 300.781 1.662339
R900G: 12821-000
R900G: 12821-100
Pilot Release