User's Manual

Table Of Contents
R900 Wall and Pit MIU Installation and Maintenance Guide 3
2 Specifications
This section provides you with the specifications for the R900 MIU.
Electrical Specifications
Transmitter Specifications
Encoder Register Interface
Power Lithium battery
Transmit Period Every 14 seconds - Single register configu-
ration
Every 11 seconds - Alternate ID #s and
meter readings for two networked register
configurations
Encoder reading ProRead (ARB VI) registers once an hour
E-Coder (ARB VII) registers every 15-minutes
1
Transmitter Channels 50
Channel Frequency 910-920 MHz
Output Power Meets FCC Part 15.247
FCC Verification Part 15.247
1
This feature may result in a minor discrepancy between the actual reading on the register and the reading on the hand-
held or mobile unit. The discrepancy results from a time lapse up to an hour between the time the MIU reads the
encoder and the time the MIU is read. This discrepancy will be corrected within the next hour when the MIU takes a
new reading
Supported Encoder Maximum Cable Length
Neptune ARB
®
V
2
300 feet (91 meters)
Neptune ProRead (ARB
®
VI)
and E-Coder (ARB
®
VII)
500 feet (152 meters)
Invensys ECR II
®
and ECR III
®3
200 feet (61 meters)
Networked Neptune ProRead (ARB VI) /
E-Coder (ARB VII)
250 feet (76 meters)
2
The length, which meets manufacturers’ published specification for wire length between encoder and remote receptacle,
is based on solid 3 conductor wire, 22 AWG.
3
Only specific formats of ECRIII programming are compatible. Contact Neptune for details.