User Manual

1600 Alabama Highway 229, Tallassee AL 36078 (334)293-6555
for leaks.
8 To activate the LCD and begin the MIU transmissions, use a
small flashlight to activate the light sensor. The light sensor is
recessed under a small hole near the center of the faceplate.
9 Test the installation as described in “Testing the ECoder)
R900i Inside Installation” on page 13.
Retrofit Meter Installation:
10 Use a punch/screwdriver and hammer to punch out the
tamper proof seal pin on the existing register head.
11 Remove the existing register by twisting counter-clockwise
12 Install the new R900i SP register head onto the meter
body in the desired orientation by twisting clockwise.
13 Test the installation as described in “Testing the ECoder)
R900i Inside Installation” on page 13.
14 Snap the new tamper-proof seal pin to secure the register to
the meter body.
The small hole is denoted on the faceplate by a flashlight symbol.
Installing the Inside Version
R900i SP Inside and Pit Installation and Maintenance Guide 13
Testing the R900i SP Inside Installation
After the MIU has been installed, follow these steps to verify that
the MIU is working properly.
1 Power up the handheld unit (HHU) test device to start the
testing program provided.
2 When the R900i SP is installed correctly, its MIU ID#
and a meter-reading appear on the HHU’s display within one
minute. Verify that this is the correct meter reading by comparing
it to the meter’s dial.
3 If a meter reading does not appear on the HHU’s display, or
the meter reading in the HHU’s display is not the same as the
reading on the meter’s dial, do the following:
• Reactivate the MIU by using a flashlight to activate the
photo sensor light.
• Verify the battery is connected.
• Test the installation again (repeat steps 1 and 2).
Completing the R900i SP Inside Installation
1 Read the MIU once more before leaving the site to ensure MIU
is transmitting.
2 Make sure the appropriate ID# on the MIU has been assigned
to the meter setting.
To avoid RF signal saturation of the HHU, position the receiver at least 2
to 3 feet from the MIU. In a densely saturated area, removing the antenna
from the handheld can assist with readings.
A register reading of 8 digits will be returned.
The light sensor is located under a small recess near the center of the dial
plate. This recess is denoted by a flashlight symbol on the dial plate.