User Manual

1600 Alabama Highway 229, Tallassee AL 36078 (334)293-6555
body in the desired orientation by twisting clockwise.
13 Test the installation as described in “Testing the ECoder)
R900i Inside Installation” on page 13.
14 Snap the new tamper-proof seal pin to secure the register to
the meter body.
The small hole is denoted on the faceplate by a flashlight symbol.
Installing the Pit Version
18 R900i SP Inside and Pit Installation and Maintenance Guide
Testing the R900i SP Pit Installation
After the MIU has been installed, follow these steps to verify that
the MIU is working properly.
1 Power up the handheld unit (HHU) test device to start the
testing program provided.
2 When the R900i SP is installed correctly, its MIU ID#
and a meter-reading appears on the HHU’s display within one
minute. Verify that this is the correct meter reading by comparing
it to the meter’s dial.
3 If a meter reading does not appear on the HHU’s display or the
meter reading in the HHU’s display is not the same as the reading
on the meter’s dial:
• Reactivate the MIU by using a flashlight to activate the
photo sensor light.
• Verify the battery is connected.
• Test the installation again (repeat steps 1 and 2).
Completing the R900i SP Pit Installation
1 Read the MIU one more time before leaving the site to ensure
MIU is transmitting.
2 Make sure the appropriate ID# on the MIU has been assigned
to the meter setting.
To avoid RF signal saturation of the HHU, position the receiver at least 2
to 3 feet from the MIU. In a densely saturated area, removing the antenna
from the handheld can assist with readings.
A register reading of 8 digits will be returned.
The light sensor is located under a small recess near the center of the dial
plate. This recess is denoted by a flashlight symbol on the dial plate.
All tags are provided to aid in the elimination of transcription errors.
R900i SP Inside and Pit Installation and Maintenance Guide 19
7 Maintenance and Troubleshooting
This section takes you through maintenance and troubleshooting procedures for
the R900i SP. The first topic will guide you through the steps necessary to
replace the battery that is in the main housing.
In addition, this section will guide you through some troubleshooting procedures
for both a six-wheel and a four-wheel encoder.
Replacing the MIU Battery (R900i SP Inside Version)
Removing the Battery Assembly:
1 Remove the tamper nail by using a small flat-blade