Model: E-Coder R900 Advanced Compliance Solutions FCC ID: P2SNTGSRFER900 FCC Part 15.247 Certification Test Report FCC ID: P2SNTGSRFER900 FCC Rule Part: 15.247 ACS Report Number: 04-039-15C Manufacturer: Neptune Technology Group, Inc.
N e p t u n e Te c h n o l o g y G r o u p I n c .
This manual is an unpublished work and contains the trade secrets and confidential information of Neptune Technology Group Inc., which are not to be divulged to third parties and may not be reproduced or transmitted in whole or part, in any form or by any means, electronic or mechanical for any purpose, without the express written permission of Neptune Technology Group Inc. All rights to designs or inventions disclosed herein, including the right to manufacture, are reserved to Neptune Technology Group Inc.
Integrated E-Coder R900 MIU Installation and Maintenance Guide Literature No. IM E-Coder R900 11.04 Part No. Neptune Technology Group Inc.
1 Product Description This section provides a general description of the Integrated E-Coder R900 MIU register (subsequently referred to Integrated E-Coder R900 MIU). The Integrated E-Coder R900 MIU by Neptune is an integrated register that contains both the E-Coder and R900 technologies in one register that collects meter reading data. It then transmits the data for collection by the meter reader.
2 Specifications This section provides you with the specifications for the Integrated E-Coder R900 MIU. Electrical Specifications Transmitter Specifications Power: Lithium battery Transmit Period: • Every 14 seconds - Single register configuration Transmitter Channels: 50 Channel Frequency: 910-920 MHz Output Power Meets: FCC Part 15.247 FCC Verification: Part 15.
Safety and Preliminary Checks Observe the following safety and preliminary checks before and during each installation: • Verify that you are at the location specified on the Site Work Order • Verify that the site is safe for you and your equipment • Notify the customer of your presence and tell the customer that you will need access to the water meter • If the Site Work Order does not have an MIU ID number on it, write in the ID number(s) of the MIU you are about to install.
6 Common Causes of Leaks If the leak indicator is flashing or continuously on, the E-Coder)R900 is indicating that a possible leak may exist. Leaks can result from various circumstances.
If Continuous Leak is repaired If a continuous leak is found and repaired, complete the following steps: 1 Use no water for at least 15 minutes. 2 Check the leak icon. 3 If the leak is OFF, then a leak is no longer indicated. 10 If Intermittent Leak is repaired If an intermittent leak is found and repaired, complete the following steps: 1 Check the leak icon after at least 24 hours. 2 If the leak has been correctly repaired, the leak icon changes from Continuous ON to Flashing.
Site Selection Installation and operation in moderate temperatures increase reliability and product life. See “Environmental Conditions” on page 4.
4. Pull up on the battery housing to unsnap the battery. 5. Slide the battery pack up over the antenna shaft. 6. Snap in the new battery by sliding it down over the antenna (see Figure ). Press down on the battery housing until you hear the snaps engage. 7. Push in a new tamper nail (see Figure ) until it snaps in place. Use of a hammer or other device may be necessary to force the tamper nail into position. 8. Reactivate the MIU as shown in Figure 20 on page 16.
Neptune Technology Group Inc. 1600 Alabama Highway 229 Tallassee, AL 36078, USA Tel: (800) 645-1892 Fax: (334) 283-7299 IM E-Coder R900 11.04 1204 Part No.Ge XXXXX-XXX w w w38 . n eR900 p t uTMnMIU e t gInstallation .com and MIM E-Coder900 © Copyright 2004, Neptune Technology Group Inc. Neptune Technology Group (Canada) Ltd. 7275 West Credit Avenue Mississauga, Ontario L5N 5M9 Canada Tel: (905) 858-4211 Fax: (905) 858-0428 Neptune Technology Group Inc. Ejército Nacional No. 418 Piso 12, Desp.