User's Manual

Safety and Preliminary Checks
Observe the following safety and preliminary checks before and during each installation:
Verify that you are at the location specified on the Site Work Order
Verify that the site is safe for you and your equipment
Notify the customer of your presence and tell the customer that you will need access to the water
meter
If the Site Work Order does not have an MIU ID number on it, write in the ID number(s) of the
MIU you are about to install. If the Site Work Order already has an MIU ID number on it, verify
that it matches the ID numbers on the MIU you are about to install
4 How to activate LCD using the light sensor
The light sensor is recessed under the small round hole near the center of the dial face. The hole is
marked with a light bulb graphic (see figure). The light sensor activates the LCD display for several
minutes when the unit is exposed to a light source. For example, a unit mounted in the basement would
turn on the LCD for several minutes after the room light is turned on. A unit mounted in an outside pit
would turn on the LCD for several minutes after the pit lid is opened exposing the unit to daylight. If the
LCD is currently off, the LCD may be reactivated by covering the dial plate with your hand for about two
seconds. In bright sunlight, it may be necessary to close the cover or the pit lid momentarily. If the LCD
does not reactivate as expected, try shining a flashlight on the light sensor.
5 How to Read
It is important to become familiar with the information available from the meter. To identify this information
the following icons and displays are helpful.
Table 2: Icons and Displays
Photo Cell, located inside the circular hole designated with the light bulb icon on the face of the Integrated
E-Coder R900 MIU, supplies the method top activate the LCD. It is activated by light.
Flow/Leak Indicator shows the direction of flow through the meter:
ON Water in use
OFF Water not in use.
Flashing Water is running slowly/low flow indication.
Leak indicator displays a possible leak:
OFF No leak indicated.
Flashing Intermittent leak indicated.
Water used during at least ½ of the 15-minute intervals in the last 24 hours (96 15-minute intervals in a
24-hour period).
Continuous
ON
Continuous leak indicated.
Water used during all 15-minute intervals in the last 24 hours.
Nine-digit LCD displays the meter reading in billing units of gallons or cubic feet.
Last three digits Testing units used for meter testing.
Fifth & Sixth reading digits
Reading units.
First four digits
Typical billing digits.