Supported Wiring
Nest Thermostat E Connectors
Conventional connectors:
Heat pump connectors:
Y1
Stage 1 compressor relay
Y1
Stage 1 compressor relay
G
Fan relay
G
Fan relay
R
24VAC power from heating/cooling
transformer*
R
24VAC power from heating/cooling
transformer*
W1
Stage 1 heat relay
W1
Stage 1 heat relay, Aux heat, Emergency heat
C
24VAC common wire
C
24VAC common wire
*/OB
Stage 2 heat (W2), Stage 2 cool (Y2)
*/OB
Changeover valve relay (Stage 1)
* No jumper wires required. You don’t need to hang on to any old jumper wires going from Rh (sometimes just called R) to Rc. Nest will
automatically jump these two connectors. Nest Thermostat E does not work with dual transformer systems.