Installation Manual

Supported Wiring
Nest Thermostat E Connectors
Heat pump connectors:
Y1
Stage 1 compressor relay
Y1
Stage 1 compressor relay
G
Fan relay
G
Fan relay
R
24VAC power from heating/cooling
transformer*
R
24VAC power from heating/cooling
transformer*
W1
Stage 1 heat relay
W1
Stage 1 heat relay, Aux heat, Emergency heat
C
24VAC common wire
C
24VAC common wire
*/OB
Stage 2 heat (W2), Stage 2 cool (Y2)
*/OB
Changeover valve relay (Stage 1)
* No jumper wires required. You don’t need to hang on to any old jumper wires going from Rh (sometimes just called R) to Rc. Nest will
automatically jump these two connectors. Nest Thermostat E does not work with dual transformer systems.
7