Owner manual
Fiber Tap
6
Connecting to the Monitoring Device
1. Connect to the Monitor Port using the included custom LC analyzer cable.
2. Connect one side of the twin-duplex ber cable into a RX port on the
monitoring device to view one side of the full-duplex link.
3. Connect the other side of the twin-duplex ber cable into another RX port
on the monitoring device to view the other side of the full-duplex link.
4. Verify that the Tap Monitor Port is cabled to the monitoring device.
Note: ________________________________________________________________
The connectors on the twin-duplex side of the custom analyzer cable contain
RX connections only. The empty TX sides are present to eliminate cabling
errors and should also be connected to the monitoring device.
______________________________________________________________________
To Monitoring Device
A B AA BB
OUT OUT OUT OUTIN IN
LASER
CAUTION!
Splitter TapSplitter Tap
www.netoptics.com
Figure 4: Connecting the Monitoring Device (LC model shown)