Installation Guide for Multi-Station Power Supply 800-0083-001 Doc. PUBPWRU Rev.
Multi-Station Power Supply Table of Contents Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Key Features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 General Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Multi-Station Power Supply PLEASE READ THESE LEGAL NOTICES CAREFULLY. By using a Net Optics Multi-Station Power Supply you agree to the terms and conditions of usage set forth by Net Optics, Inc. No licenses, express or implied, are granted with respect to any of the technology described in this manual. Net Optics retains all intellectual property rights associated with the technology described in this manual. This manual is intended to assist with installing Net Optics products into your network.
Multi-Station Power Supply Introduction Get rid of the brick pile with Net Optics Multi-Station Power Supply. This dual AC input Power Supply provides multiple DC power leads in a rack-mountable 1U chassis. The Power Supply supports single or redundant power connections compatible with Net Optics’ rack-mountable Taps, Port Aggregator Taps, and Dual Port Aggregator Taps. Compatible with 100-230 VAC input, the Multi-Station Power Supply delivers 350 Watts of power to Net Optics 12 VDC devices worldwide.
Multi-Station Power Supply General Description The AC version of the product accepts power from two AC line sources. The unit can operate from either one or both AC power sources. The power inputs are “universal,” accepting 85-264 VAC, 47-63 Hz. The DC version of the product accepts power from two DC sources. The unit can operate from either one or both DC power sources. The input voltages can be from -32 to -72VDC amd is compatible with most telecommunications equipment rooms.
Multi-Station Power Supply Product Diagrams Multi-Station Power Chassis 2 1 www.netoptics.
Multi-Station Power Supply Product Diagrams 10/100 Ethernet Tap Power 1 Dual Power for Redundancy DC connector leads DC connector leads Power 2 Figure 4: Connecting Power to Taps Installation To install the Multi-Station Power Supply, you simply need to connect the input power and plug the DC output connector leads into supported Net Optics devices. Details of these procedures are given in the following sections.
Multi-Station Power Supply Connecting the Multi-Station Power Supply to Net Optics Taps 1. Unpack the Multi-Station Power Supply, and verify that you have all the necessary components to successfully install the Taps. 2. Connect one of the DC connector leads from Power 1 into the DC jack 1 on the first Tap. If present, remove the rubber cap from the barrel connector before plugging it into the Tap. 3. Connect one of the DC connector leads from Power 2 into the DC jack 2 on the first Tap.
Multi-Station Power Supply Note:_________________________________________________________________ Each AC power source should be independent of the other in order to have power redundancy. If you do not require power redundancy, the unit can be operated with a single power cord connected to a single AC power source. In this case, either AC power connector on the rear of the Multi-Station Power Supply may be used for the connection.
Multi-Station Power Supply Note:_________________________________________________________________ Each DC power source should be independent of the other in order to have power redundancy. If you do not require power redundancy, the unit can be operated with a single power cable connected to a single DC power source. In this case, either DC power block on the rear of the Multi-Station Power Supply may be used for the connection.
Multi-Station Power Supply Symbols on product Indicates WEEE compliance Indicates CE compliance Indicates RoHS compliance Indicates C-Tick compliance Indicates VCCI compliance Indicates MET compliance (U.S.A.
Multi-Station Power Supply Specifications Environment Operating Temperature: 0˚C to 40˚C Storage Temperature: -20˚C to 85˚C Relative Humidity: 10% min, 95% max, non-condensing Mechanical Dimensions: 1.75” high x 12.5” deep x 17” wide Power AC input: 85-264 VAC, 47-63 Hz, 5 A max @ 115 VAC, 2.50A max @ 230 VAC DC input: -48VDC nominal, -36 to -72VDC, 12.2 A max @ 36 VDC, 5.8 A max @ 72 VDC DC output: 12V, 3.6A per lead (AC model), 2.
Multi-Station Power Supply Limitations on Warranty and Liability Net Optics offers a limited warranty for all its products. IN NO EVENT SHALL NET OPTICS, INC. BE LIABLE FOR ANY DAMAGES INCURRED BY THE USE OF THE PRODUCTS (INCLUDING BOTH HARDWARE AND SOFTWARE) DESCRIBED IN THIS MANUAL, OR BY ANY DEFECT OR INACCURACY IN THIS MANUAL ITSELF.