User Manual
Model FS526T FS728TLP FS728TP FS750T2
Strick, or WRR (Weighted Round Robin) Both WRR
Auto-VoIP
Yes,basedonprotocols(SIP,H323andSCCP)oronOUIbytes(default
database and user-based OUIs) in the phone source MAC address
No
Auto Video Yes Yes No No
Port Mirroring (ingress and egress) Yes
IEEE NETWORK PROTOCOLS
•IEEE 802.3 Ethernet
•IEEE 802.3i 10BASE-T
•IEEE 802.3u 100BASE-T
•IEEE 802.3ab 1000BASE-T
•IEEE 802.1Q VLAN Tagging
•IEEE 802.3x Full-duplex Flow Control
•IEEE 802.3z Gigabit Ethernet 1000BASE-SX/LX
•IEEE 802.3ad Trunking (LACP)
•IEEE 802.1AB LLDP with ANSI/TIA-1057 (LLDP-MED)
•IEEE 802.1p Class of Service
•IEEE 802.3 af (PoE)
•IEEE 802.1D Spanning Tree (STP)
•IEEE 802.1s Multiple Spanning Tree (MSTP) (FS728TP Only)
•IEEE 802.1w Rapid Spanning Tree (RSTP)
•IEEE 802.1x (MD5) Radius network access control (except FS750T2)
MANAGEMENT
Password management Yes
Configurable Management VLAN Yes No
Admin access control via Radius Yes No
Admin access control via TACACS+ No Yes No
Web browser-based graphical user interface
(GUI)
Yes
Smart Control Center (SCC) for
multi-switch management
Yes SmartWizard
®
Dual Soware (firmware) image Yes No
Dual Configuration file No
Cable Test utility Yes No
File transfers (uploads, downloads) TFTP/HTTP TFTP only
HTTPDownload(rmware) Yes No
LEDs
Per port Speed, Link, Activity
Per device Power, Fan and PoE Power Status (PoE model only)
PHYSICAL SPECIFICATIONS
Weight (kg) 1.35 2.92 3.57 3.2
Dimensions(WxDxH)mm 326x168x43 440x204x43 440x257x43 440x205x43
POWER CONSUMPTION (WHEN ALL PORTS USED, LINE-RATE TRAFFIC AND MAX POE IF APPLICABLE)
Worst case, all ports used, line-rate trac,
max PoE
12w 124w 256w 19.65w
Technical Specifications
ProSAFE
®
Fast Ethernet Smart Managed Switches Data Sheet
FS526T, FS728TLP, FS728TP and FS750T2
Page 7 of 9