Configure Switching Information User Manual183
The VLAN name can be up to 32 alphanumeric characters long, including blanks. The
default is blank. VLAN ID 1 always uses the name Default.
The VLAN Type field identifies the type of the VLAN you are configuring. You cannot
change the type of the default VLAN (VLAN ID = 1): it is always type Default. When you
create a VLAN using this page, its type is always Static. A VLAN that is created by GVRP
registration initially uses a type of Dynamic. When configuring a dynamic VLAN, you can
change its type to Static.
9. Click the Add button.
The VLAN is added to the switch.
10. Click the Apply button.
Your settings are saved.
Reset the VLAN Configuration to Default Setting
To reset the VLAN configuration to default settings:
1. Launch a web browser
.
2. In the address field of your web browser
, enter the IP address of the switch.
The login window opens.
3. Enter admin as the user name, enter your local device password,
and click the Login
button.
The first time that you log in, no password is required. However, you then must specify a
local device password to use each subsequent time that you log in.
The System Information page displays.
4. Select Switching> VLAN >
Advanced > VLAN Configuration.
5. Select the Reset Configuration check box.