M4300 Intelligent Edge Series Fully Managed Stackable Switches
Configure Switching Information User Manual205
The System Information page displays.
4. Select Switching >
Auto-VoIP > OUI-based > OUI Table.
5. In the T
elephony OUI(s) field, specify the VoIP OUI prefix to be added in the format
AA:BB:CC.
Up to 128 OUIs can be configured.
6. In the Description field, enter the description for the OUI.
The maximum length of description is 32 characters. The following OUIs are present in
the configuration by default:
00:01:E3 - SIEMENS
00:03:6B - CISCO1
00:12:43 - CISCO2
00:0F:E2 - H3C
00:60:B9 - NITSUKO
00:D0:1E - PINTEL
00:E0:75 - VERILINK
00:E0:BB - 3COM
00:04:0D - AVAYA
1
00:1B:4F - AVAYA
2
7. Click the Add button.