User Manual

Table Of Contents
M4300 Intelligent Edge Series Fully Managed Stackable Switches
Configure Multicast Routing User Manual461
11. Enter the Startup Query Count value to indicate the configured number of queries sent out
on startup, separated by the startup query interval.
The default value is 2.
12. In the Last Member Query Interval field, enter the last member query interval in
milliseconds.
This is the maximum response time to be inserted into group-specific queries sent in
response to leave group messages, and is also the amount of time between
group-specific query messages. V
alid values are from 0 to 655355. The default value is
1000 milliseconds.
13. In the Last Member Query Count field, enter the number of queries to be sent on receiving
a leave group report.
Valid values are from 1 to 20. The default value is 2.
14. Click the Apply button.
Your settings are saved.
The following table describes the nonconfigurable information that is displayed.
View IPv6 MLD Routing Interface Statistics
To view the IPv6 multicast MLD routing interface statistics:
1. Launch a web browser
.
2. In the address field of your web browser
, enter the IP address of the switch.
The login window opens.
3. Enter admin as the user name, enter your local device password,
and click the Login
button.
The first time that you log in, no password is required. However, you then must specify a
local device password to use each subsequent time that you log in.
The System Information page displays.
4. Select Routing> IPv6 Multicast > MLD > Routing Interface Statistics.
Table 176. IPv6 MLD Routing Interface Configuration
Field Description
Operational Mode The operational status of MLD on the Interface.
Robustness The robustness parameter for the selected interface. This variable allows
tuning for the expected packet loss on a subnet. If a subnet is expected to
be lossy
, the robustness variable can be increased. MLD is robust to
robustness variable –1 packet losses. The default value is 2.