User Manual

Table Of Contents
M4300 Intelligent Edge Series Fully Managed Stackable Switches
Maintenance and Troubleshooting User Manual688
5. Select the Ping type from the list.
Possible values are as follows:
Global. Ping a global IPv6 address.
Link Local. Ping a link-local IPv6 address over the specified interface.
This field is
shown when Interface is selected as the ping option.
6. Use IPv6 Address/Hostname to enter the IPv6 address or host name of the station for the
switch to ping.
The initial value is blank. The format is xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx. The
maximum number of characters is 255.
7. Use Count to enter the number of echo requests send.
The range is 1 to 15. The default value is 3.
8. Enter the Interval in seconds between ping packets.
The range is 1 to 60. The default value is 3.
9. Use Datagram Size to enter the datagram size.
The valid range is 0 to 13000. The default value is 0 bytes.
10. Enter the Source IP address or interface to use when sending the echo request packets.
If the source is not required, select None as the source option. Possible values are as
follows:
None.
The source address of the ping packet would be the address of the default
outgoing interface.
IPv6 Address.
The source IPv6 address to use when sending the echo request
packets. This field is shown when IPv6 Address is selected as the source option.
Interface.
The interface to use when sending the echo request packets. This field is
shown when Interface is selected as the source option.
Note: Values configured in the fields on this page are not saved to the switch.