User Manual

Table Of Contents
Configure System Information
79
M4100 Series Managed Switch
The Unit list displays the current PoE unit.
8. T
o change the PoE unit, select another unit from the menu.
9. In the System Usage Threshold field, enter a number from 1 to 99.
This sets the threshold level at which a trap is sent if consumed power is greater than the
threshold power
.
10. Select the Power Management Mode Dynamic or Static radio button.
This setting describes or controls the power management algorithm used by the PSE to
deliver power to the requesting PDs.
Dynamic.
The power consumption on each port is measured and calculated in real
time.
Static.
The power allocated for each port depends on the type of power threshold
configured on the port.
11. Select the
Traps Enable or Disable radio button.
Enable activates the PoE traps. Disable deactivates the PoE traps. The default setting is
enabled.
12. Click the APPL
Y button.
The updated configuration is sent to the switch. Configuration changes take effect
immediately
.