Smart Managed Pro Switches MS510TX and MS510TXPP
Configure System Information User Manual52
3. In the address field of your web browser, enter the IP address of the switch.
If you do not know the IP address of the switch, see
Access the Switch on page 14.
The login window opens.
4. Enter
the switch’s password in the Password field.
The default password is password.
The System Information page displays.
5. Select System
> Management > Green Ethernet > Green Ethernet Summary.
The Green Mode Statistics Summary page displays. The page shows
the Green Ethernet
Interface Summary section.
6. To refresh the page, click the Refresh button.
The following table describes the nonconfigurable fields.
Table 14. Green Ethernet Statistics Summary information
Field Description
Cumulative Energy Saving
(W
atts*Hours)
The estimated cumulative energy saved in watts * hours when all green
modes are enabled.
Interface The interface for which data is displayed or configured.
Energy Detect Admin mode Shows whether Energy Detect mode is enabled or disabled on the port.
If this mode is enabled and the port link goes down, the PHY
automatically goes down for a short period of time, then wakes up to
check link pulses.
This allows the switch to perform autonegotiation
and save power consumption when no link partner is present.
Energy Detect Operational Status The current operational status of the Energy Detect mode.
Short Reach Admin mode Shows whether Short Reach Admin mode is enabled or disabled on the
port. When this mode is enabled, the PHY is forced to operate in low
power mode irrespective of the cable length.
Short Reach Operational Status The current operational status of the Short Reach mode.
EEE Admin mode Shows whether Energy Efficient Ethernet mode is enabled or disabled
on the port. When this mode is enabled, the port transitions to low
power mode during link idle conditions.
Use the Device View
For information about the device view, see Local Browser Interface Device View on page 21.