Operation Manual
Defaults and Technical Specifications
89
ReadyNAS OS 6 Desktop Storage Systems
Power consumption:
• BTU at full power supply utilization: 110.66 W
• In operation: 54.94 W
• Power off (Wake On LAN): 804.64 mW
• Power off: 338.42 mW
Electrical:
• Internal 200 W server-rated AC power supply
• Input: 100–240V AC, 50/60 Hz
Environmental requirements:
• Operating temperature: 0 to 40°C (32° to 104°F)
• Operating humidity: 20 to 80% relative humidity (non-condensing)
• Storage temperature: –20 to 70°C (–4 to 158°F)
• Storage humidity: 5 to 95% relative humidity (non-condensing)
• Software controlled 120 mm chassis cooling fan
Certifications:
• FCC Class B, CE Class B, RoHS, VCCI Class B
ReadyNAS 516 Technical Specifications
The ReadyNAS 516 storage system meets the following technical specifications:
General:
• Intel Core i3 3.3 GHz Dual Core CPU
• 4GB ECC memory
• Six-bay storage
• Three E-SATA ports
• One HDMI port
• One USB 2.0 port (front)
• Two USB 3.0 ports (back)
• Two LAN ports
• LCD display
• Infrared remote receiver
• Proximity sensor